Project Scope
This project featured the installation of the Rooflogic Ultratherm MSR System, incorporating a high-performance assembly of materials designed for thermal efficiency, acoustic performance, and durability. The system includes Colorcote Topdeck T profile roof, Vapour Control Layer, Acoustic Board, PIR Board, Roof Underlay & Zincalume Linerdeck.
A key deviation from standard practice was the horizontal installation of the Zincalume the Linerdeck, which is typically installed vertically.
The roof scope involved complex roof geometries with multiple rakes requiring precise detailing & execution. To complement the system & ensure weathertightness & design integrity, bespoke aluminium flashings were fabricated & installed.
SPECS
666m² of Rooflogic Ultratherm MSR Roofing
180m² of Alsynite Topglass GC Ultrasafe Clear Sheeting
134m of Colorcote 175mm Box Gutter with 80mm & 100mm Downpipes
Contracted by
Marra Construction (2004) Ltd